Základní informace
- Thermal Dissipation Coefficient : 20KW
- Liquid Cooled Platform : Gun Drilled -DUAL 10x500x10mm Pass
- 2 x 3rd Gen Intel Xeon Scalable Platinum 8380 Processor (40 cores)
- High Memory Capacity DDR4 768GB ( 2667 MHz )
- 4 x NVIDIA TESLA T4 GPU
- MIL-STD 461 18V to 36V DC-DC 800W
- NVMe SSD (4GB/s) 80TB
- Liquid Cooling Designed
- Conduction Cooled Technology
- MIL-STD 810 Anti-vibration / Shock
The global transformation is rapidly scaling the demands for flexible computer, networking, and storage. Future workloads will necessitate infrastructures that can seamlessly scale to support immediate responsiveness and widely diverse performance requirements. The exponential growth of data generation and consumption, the rapid expansion of cloud-scale computing and 5G networks, and the convergence of high-performance computing (HPC) and artificial intelligence (AI) into new usages requires that today’s data centers and networks evolve now— or be left behind in a highly competitive environment.
AV3000 enables a new level of consistent, pervasive, and breakthrough performance in new AI inference to implement machine learning and deep learning. In addition to Tesla T4, AV3000 provides one M.2 NVMe slot for fast storage access. Combining stunning inference performance, powerful CPU and expansion capability, it is the perfect ruggedized platform for versatile edge AI applications.
AV3000 ruggedized AI inference platforms designed for advanced inference acceleration applications such as voice, video, image and recommendation services. It supports NVIDIA® Tesla T4 GPU, featuring 8.1 TFLOPS in FP32 and 130 TOPs in INT8 for real-time inference based on trained neural network model.
Video
Specifikace
Processor |
2 x 3rd Gen. Intel® Xeon® Scalable Platinum 8380 CPU(2.3 GHz, 40Cores, TDP 270W) |
||
LAN |
Dual LAN with 1GbE LAN with Intel® X722 |
||
Memory |
768 GB DDR4-RDIMM( 2667 MHz ) |
||
Storage |
80 TB NVMe |
||
4 x TESLA GPU Card | |||
---|---|---|---|
NVIDIA |
TESLA T4 |
||
Tensor Core |
320 |
||
CUDA Cores |
2560 |
||
Memory |
16GB GDDR6, 300 GB/Sec. |
||
GPU 1 |
PCIex16 – A3 Slot |
||
GPU 2 |
PCIex 8 – A4 Slot |
||
GPU 3 |
PCIex16 – A5 Slot |
||
GPU 4 |
PCIex 8 – A6 Slot |
||
Storage Configurations | |||
4x 8TB U.2 = 32TB |
PCIe x 16 – A1 (4xPorts PCIe U.2 Riser Card ) |
||
4x 8TB U.2 = 32TB |
PCIe x 16 – A2 (4xPorts PCIe U.2 Riser Card) |
||
1x 8TB U.2 = 8TB |
On Board OCuLink |
||
1x 8TB U.2 = 8TB |
On Board OCuLink |
||
PSU | |||
PSU |
MIL-461 800W DC-DC 18V~36V Power module |
||
Physical | |||
Dimension |
416.2 x 206.4 x 506.4mm (W x D x H) |
||
Weight |
15KG |
Finish |
Anodic aluminum oxide |
Chassis |
Aluminum Alloy, Corrosion Resistant. |
||
REAR I/O | |||
LAN | 2 x RJ45 Gigabit Etherne | ||
USB |
4 x USB 2.0 ports (2 rear + 2 via headers) 5 x USB 3.2 Gen1 ports (2 rear + 2 via headers + 1 Type A) |
||
VGA | 1 x VGA | ||
COM | 2x COM(RS232) | ||
Expansion slot (By Request) | |||
SATA connector x2 available | |||
iPass cable connector x3 | |||
NvME slot x1 |
MIL Compliance
MIL-STD-810G (Operation Test) | ||||||
---|---|---|---|---|---|---|
Low Temp. |
Method 502.5 Procedure 2 |
Exposure(24H x 3 cycle) at -10℃ min. |
||||
High Temp. |
Method 501.5 Procedure 2 |
60ºC for 2 Hrs after temperature stabilization. |
||||
Humidity |
Method 507.5 Procedure 2 |
RH -95%. Test cycles: ten 24-hrs , functional test after 5th and 10th cycles |
||||
Vibration |
Method 514.6 Category 20 |
10-500Hz 1.04Grms Test duration: 1 Hr x 3 axis (total 3 Hrs) |
||||
Shock |
Method 516.6 Procedure 1 |
20G, 11mSec, 3 per axis |
||||
MIL-STD-810G (Non-Operating Tests) | ||||||
Low Temp. |
Method 502.5 |
Exposure(24H x 7 cycle) at -20℃ min. |
||||
High Temp. |
Method 501.5 Procedure 1 |
71ºC for 2 Hrs after temperature stabilization. |
||||
Vibration |
Method 514.6 Category 24 |
200 to 2000Hz Test duration: 1hr per axis; rms = 7.7 Gs |
||||
Shock |
Method 516.6 Procedure 1 |
20G, 11mSec, 3 per axis |
||||
MIL-STD-461E | ||||||
CE102 |
Basic curve, 10kHz - 30 MHz |
|||||
RE102-4, (1.5 MHz) |
(1.5 MHz) -30 MHz - 5 GHz |
|||||
RS103 |
1.5 MHz - 5 GHz, 50 V/m equal for all frequencies EN 61000-4-2: Air discharge: 8 kV |
|||||
Environmental Qualifications | ||||||
Regulatory |
CE ,FCC Compliance |
|||||
Operation Temp. |
-20°C to 50°C |
|||||
Storage Temp. |
-40°C to 85 °C |
|||||
Green Product |
RoHS, WEEE compliance |